Liquid argon detectors rely on wavelength shifters for efficient detection of scintillation light. The current standard is tetraphenyl butadiene (TPB), but it is challenging to instrument on a large scale. Poly(ethylene 2,6-naphthalate) (PEN), a polyester easily manufactured as thin sheets, could simplify the coverage of large surfaces with wavelength shifters. Previous measurements have shown that commercial grades of PEN have approximately 50% light conversion efficiency relative to TPB. Encouraged by these results, we conducted a large-scale measurement using 4 m2 combined PEN and specular reflector foils in a two-tonne liquid argon dewar to assess its stability over approximately two weeks. This test is crucial for validating PEN as a viable substitute for TPB. The setup used for the measurement of the stability of PEN as a wavelength shifter is described, together with the first results, showing no evidence of performance deterioration over a period of 12 days.

Demonstration of the light collection stability of a PEN-based wavelength shifting reflector in a tonne scale liquid argon detector

M. B. Walczak
2025-01-01

Abstract

Liquid argon detectors rely on wavelength shifters for efficient detection of scintillation light. The current standard is tetraphenyl butadiene (TPB), but it is challenging to instrument on a large scale. Poly(ethylene 2,6-naphthalate) (PEN), a polyester easily manufactured as thin sheets, could simplify the coverage of large surfaces with wavelength shifters. Previous measurements have shown that commercial grades of PEN have approximately 50% light conversion efficiency relative to TPB. Encouraged by these results, we conducted a large-scale measurement using 4 m2 combined PEN and specular reflector foils in a two-tonne liquid argon dewar to assess its stability over approximately two weeks. This test is crucial for validating PEN as a viable substitute for TPB. The setup used for the measurement of the stability of PEN as a wavelength shifter is described, together with the first results, showing no evidence of performance deterioration over a period of 12 days.
2025
Noble liquid detectors (scintillation, ionization, double-phase); Dark Matter detectors (WIMPs, axions, etc.); Neutrino detectors
File in questo prodotto:
File Dimensione Formato  
2025_JInst_20_Gupta.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.94 MB
Formato Adobe PDF
1.94 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12571/36904
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact