Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
Using 347: 5 fb(-1) of data recorded by the BABAR detector at the PEP-II electron-positron collider, 244 x 10(3) signal events for the D+ -> K- pi(+)e(+)nu(e) decay channel are analyzed. This decay mode is dominated by the (K) over bar*(892)(0) contribution. We determine the (K) over bar*(892)(0) parameters: m(K*(892)0) (895.4 +/- 0.2 +/- 0.2) MeV/c(2),Gamma(0)(K*(892)0) (46.5 +/- 0.3 +/- 0.2) MeV/c(2), and the Blatt-Weisskopf parameter r(BW) = 2.1 +/- 0.5 +/- 0.5 (GeV/c)(-1), where the first uncertainty comes from statistics and the second from systematic uncertainties. We also measure the parameters defining the corresponding hadronic form factors at q(2) = 0 (r(V) = V(0)/A(1)(0) = 1.463 +/- 0.031, r(2) = A(2)(0)/A(1)(0) = 0.801 +/- 0.020 +/- 0.020) and the value of the axial-vector pole mass parametrizing the q(2) variation of A(1) and A(2): m(A) (2.63 +/- 0.10 +/- 0.13) GeV/c(2). The S-wave fraction is equal to (5.79 +/- 0.16 +/- 0: 15)%. Other signal components correspond to fractions below 1%. Using the D+ -> K-pi(+)pi(+) channel as a normalization, we measure the D+ semileptonic branching fraction: B(D+ K-pi(+)e(+)nu(e)) (4.00 +/- 0: 03 +/- 0.04 +/- 0.09) x 10(-2), where the third uncertainty comes from external inputs. We then obtain the value of the hadronic form factor A(1) at q(2) 0: A(1)(0) 0.6200 +/- 0.0056 +/- 0.0065 +/- 0.0071. Fixing the P-wave parameters, we measure the phase of the S wave for several values of the K pi mass. These results confirm those obtained with K pi production at small momentum transfer in fixed target experiments.
Analysis of the D+ -> K- pi(+) e(+) nu(e) decay channel
Using 347: 5 fb(-1) of data recorded by the BABAR detector at the PEP-II electron-positron collider, 244 x 10(3) signal events for the D+ -> K- pi(+)e(+)nu(e) decay channel are analyzed. This decay mode is dominated by the (K) over bar*(892)(0) contribution. We determine the (K) over bar*(892)(0) parameters: m(K*(892)0) (895.4 +/- 0.2 +/- 0.2) MeV/c(2),Gamma(0)(K*(892)0) (46.5 +/- 0.3 +/- 0.2) MeV/c(2), and the Blatt-Weisskopf parameter r(BW) = 2.1 +/- 0.5 +/- 0.5 (GeV/c)(-1), where the first uncertainty comes from statistics and the second from systematic uncertainties. We also measure the parameters defining the corresponding hadronic form factors at q(2) = 0 (r(V) = V(0)/A(1)(0) = 1.463 +/- 0.031, r(2) = A(2)(0)/A(1)(0) = 0.801 +/- 0.020 +/- 0.020) and the value of the axial-vector pole mass parametrizing the q(2) variation of A(1) and A(2): m(A) (2.63 +/- 0.10 +/- 0.13) GeV/c(2). The S-wave fraction is equal to (5.79 +/- 0.16 +/- 0: 15)%. Other signal components correspond to fractions below 1%. Using the D+ -> K-pi(+)pi(+) channel as a normalization, we measure the D+ semileptonic branching fraction: B(D+ K-pi(+)e(+)nu(e)) (4.00 +/- 0: 03 +/- 0.04 +/- 0.09) x 10(-2), where the third uncertainty comes from external inputs. We then obtain the value of the hadronic form factor A(1) at q(2) 0: A(1)(0) 0.6200 +/- 0.0056 +/- 0.0065 +/- 0.0071. Fixing the P-wave parameters, we measure the phase of the S wave for several values of the K pi mass. These results confirm those obtained with K pi production at small momentum transfer in fixed target experiments.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: http://hdl.handle.net/20.500.12571/1700
Citazioni
ND
41
29
social impact
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2021-2023 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.