Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
Using the entire sample of 467 x 10(6) Y(4S) -> B (B) over bar decays collected with the BABAR detector at the PEP-II asymmetric-energy B factory at the SLAC National Accelerator Laboratory, we perform an analysis of B-+/- -> DK +/- decays, using decay modes in which the neutral D meson decays to either CP-eigenstates or non-CP-eigenstates. We measure the partial decay rate charge asymmetries for CP-even and CP-odd D final states to be A(CP+) = 0.25 +/- 0.06 +/- 0.02 and A(CP-) = 0.09 +/- 0.07 +/- 0.02, respectively, where the first error is the statistical and the second is the systematic uncertainty. The parameter A(CP+) is different from zero with a significance of 3.6 standard deviations, constituting evidence for direct CP violation. We also measure the ratios of the charged-averaged B partial decay rates in CP and non-CP decays, RCP+ 1.18 +/- 0.09 +/- 0.05 and RCP- = 1.07 +/- 0.08 +/- 0.04. We infer frequentist confidence intervals for the angle gamma of the unitarity triangle, for the strong phase difference delta(B), and for the amplitude ratio r(B), which are related to the B- -> DK- decay amplitude by r(B)e(i(delta B-gamma)) = A(B- -> (D) over bar K-0(-)) = A(B- -> (D) over bar K-0(-))/A(B- -> (DK-)-K-0). Including statistical and systematic uncertainties, we obtain 0: 24 < rB < 0: 45 ( 0: 06 < rB < 0: 51) and, modulo 180 degrees, 11.3 degrees < gamma < 22.7 degrees or 80.8 degrees < gamma < 99.2 degrees or 157.3 degrees < gamma < 168.7 degrees (7.0 degrees < gamma < 173.0 degrees) at the 68% ( 95%) confidence level.
Measurement of CP observables in B-+/- -> DCPK +/- decays and constraints on the CKM angle gamma
Using the entire sample of 467 x 10(6) Y(4S) -> B (B) over bar decays collected with the BABAR detector at the PEP-II asymmetric-energy B factory at the SLAC National Accelerator Laboratory, we perform an analysis of B-+/- -> DK +/- decays, using decay modes in which the neutral D meson decays to either CP-eigenstates or non-CP-eigenstates. We measure the partial decay rate charge asymmetries for CP-even and CP-odd D final states to be A(CP+) = 0.25 +/- 0.06 +/- 0.02 and A(CP-) = 0.09 +/- 0.07 +/- 0.02, respectively, where the first error is the statistical and the second is the systematic uncertainty. The parameter A(CP+) is different from zero with a significance of 3.6 standard deviations, constituting evidence for direct CP violation. We also measure the ratios of the charged-averaged B partial decay rates in CP and non-CP decays, RCP+ 1.18 +/- 0.09 +/- 0.05 and RCP- = 1.07 +/- 0.08 +/- 0.04. We infer frequentist confidence intervals for the angle gamma of the unitarity triangle, for the strong phase difference delta(B), and for the amplitude ratio r(B), which are related to the B- -> DK- decay amplitude by r(B)e(i(delta B-gamma)) = A(B- -> (D) over bar K-0(-)) = A(B- -> (D) over bar K-0(-))/A(B- -> (DK-)-K-0). Including statistical and systematic uncertainties, we obtain 0: 24 < rB < 0: 45 ( 0: 06 < rB < 0: 51) and, modulo 180 degrees, 11.3 degrees < gamma < 22.7 degrees or 80.8 degrees < gamma < 99.2 degrees or 157.3 degrees < gamma < 168.7 degrees (7.0 degrees < gamma < 173.0 degrees) at the 68% ( 95%) confidence level.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12571/1342
Citazioni
ND
54
33
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.