This paper reports on the development of a technology involving -enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ( ), high optical quality, radiopure -containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2–0.4 kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the Q-value of the double-beta transition of (3034 keV) is 4–6 keV FWHM. The rejection of the -induced dominant background above 2.6 MeV is better than . Less than μ activity of and in the crystals is ensured by boule recrystallization. The potential of -enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only exposure: the two neutrino double-beta decay half-life of has been measured with the up-to-date highest accuracy as = [6.90 ± 0.15(stat.) ± 0.37(syst.)] . Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of Mo .
Development of100Mo -containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
Pagnanini, L.;
2017-01-01
Abstract
This paper reports on the development of a technology involving -enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ( ), high optical quality, radiopure -containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2–0.4 kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the Q-value of the double-beta transition of (3034 keV) is 4–6 keV FWHM. The rejection of the -induced dominant background above 2.6 MeV is better than . Less than μ activity of and in the crystals is ensured by boule recrystallization. The potential of -enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only exposure: the two neutrino double-beta decay half-life of has been measured with the up-to-date highest accuracy as = [6.90 ± 0.15(stat.) ± 0.37(syst.)] . Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of Mo .File | Dimensione | Formato | |
---|---|---|---|
2017_EurPhysJC_77_Armengaud.pdf
accesso aperto
Licenza:
Creative commons
Dimensione
2.48 MB
Formato
Adobe PDF
|
2.48 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.